Academy › Topic library › Going Deeper: Gauge R&R by the Numbers
Q-BOT ACADEMY · FREE VIDEO LESSON · 14 MIN
Going Deeper: Gauge R&R by the Numbers
Because a gauge answers two different questions. One: is this part good or bad? For that, compare the measurement error to the tolerance. Two: can we see the process change, and can we see an improvement work? For that, compare the error to the spread of the process. Same gauge, two questions, and the numbers can give two different answers!
In short
Variances add: gauge R and R squared is repeatability squared plus reproducibility squared. The average and range method uses R double bar, X diff and the range of the part averages, times K one, K two and K three. ANOVA turns mean squares into variance components, and checks the interaction first. Read the yardstick that fits the job, and want five or more distinct categories. Then check bias and linearity, because precise isn't the same as accurate!
Check yourself
A slat micrometer study gives a gauge R and R standard deviation of zero point oh two millimeters. The slat tolerance is one millimeter, eighteen and a half to nineteen and a half. What's the percent tolerance? A, two percent. B, twelve percent. C, twenty percent. Or D, one point two percent.
Show the answer
The answer is B, twelve percent. Six times zero point oh two is zero point one two millimeters, and zero point one two over one is twelve percent. That's in the ten to thirty band, so it may be OK, depending on the use and the cost. A forgot the six. C used ten instead of six. And D slipped a decimal place. That's gauge R and R by the numbers. Questions? Ask Q-Bot right here in the Academy. And one for the road: why does the good gauge get invited to every study? It gives the same answer, no matter who asks!
Where this topic is taught
This lesson is part of every free Academy course whose Body of Knowledge covers it. Each course puts it in context, with exercises and checks.
Full lesson transcript
The narration from the video, by chapter. Brindlewood Outdoor Furniture and its people are a fictional company used in every Q-Bot Academy lesson.
Intro
Brindlewood, a Monday morning in the lab. Priya's new coating thickness gauge sits on the bench, still in its foam. Rosa picks it up. Last week this thing read about four hundredths of a mil higher than the old one. So which one do we trust? Marcus pulls up a spreadsheet. We don't trust either one yet. We test it, and this time, we do it by the numbers!
Hey there, I'm Q-Bot. Welcome to the Q-Bot Academy. Today we're going deeper: gauge R and R by the numbers! We'll work a full study two ways, the average and range method and the ANOVA method, read the three yardsticks and the number of distinct categories, then test a gauge for bias and linearity. If measurement system analysis is new to you, start with the measurement system analysis and gauge R and R video.
Why do the math?
Why do the math at all? Because a gauge answers two different questions. One: is this part good or bad? For that, compare the measurement error to the tolerance. Two: can we see the process change, and can we see an improvement work? For that, compare the error to the spread of the process. Same gauge, two questions, and the numbers can give two different answers!
The model
First, the model. Every reading equals the true value of the part, plus an operator effect, plus an operator-by-part interaction, plus a little repeat error. And variances add, not standard deviations. So the total variance equals the part variance plus the gauge R and R variance. And gauge R and R splits again: repeatability, the equipment, plus reproducibility, the people. That's why every result comes back as a square root of a sum of squares.
Worked example 1: the new coating gauge
Worked example one: the new coating gauge. Priya marks ten Harbor chair frames, picked to cover the whole coating range, from about two point six to three point seven mils. Three appraisers, Priya, Tomas and Jada, each measure every frame twice, at a marked spot, in random order, without seeing their earlier readings. That's sixty readings. The spec is two point five to four point oh mils, so the tolerance is one and a half mils.
The average and range method
Method one: average and range. For each person and each frame, take the range of the two trials. The average of all thirty ranges, R double bar, is zero point oh one seven mils. Repeatability, or equipment variation, E V, equals R double bar times a constant, K one. With two trials, K one is zero point eight eight six two, which is one over d two star. So E V is zero point oh one seven times zero point eight eight six two: about zero point oh one five mils.
Next, reproducibility, or appraiser variation, A V. Take each person's overall average. Tomas reads highest at three point one seven oh five, Jada lowest at three point one four two five, so the difference, X diff, is zero point oh two eight. Multiply by K two, zero point five two three one for three appraisers, and square it. Then subtract E V squared over the number of parts times trials, because a bit of repeatability hides in those averages. The square root gives A V, about zero point oh one four mils.
Now put them together. Gauge R and R is the square root of E V squared plus A V squared: about zero point oh two one mils. Part variation, P V, uses the range of the ten frame averages, about one point one oh mils, times K three, zero point three one four six for ten parts: about zero point three four five. Total variation is the square root of gauge R and R squared plus P V squared. Six times zero point oh two oh seven is zero point one two four, which is eight point three percent of the tolerance. Nice!
The ANOVA method
Method two: ANOVA. Software splits the total sum of squares into four pieces: frames, operators, the operator-by-frame interaction, and repeatability. Frames take nine degrees of freedom, operators two, the interaction eighteen, and repeatability thirty. Each sum of squares over its degrees of freedom gives a mean square. Frames dominate, at about zero point eight oh two. The interaction is zero point oh oh oh three three, and repeatability zero point oh oh oh two nine five.
First check the interaction. F is the interaction mean square over the repeatability mean square: about one point one two, with eighteen and thirty degrees of freedom. The p-value is about zero point three eight, so we fail to reject. This F test assumes the repeat errors are roughly normal, with the same spread for everyone. There's no evidence of an interaction, so the software pools it into repeatability, now with forty eight degrees of freedom. If the interaction had been significant, you'd keep it, and it would count as part of reproducibility.
Now turn mean squares into variance components. Repeatability is the pooled error mean square. The operator variance is the operator mean square minus the error mean square, over parts times trials, twenty. The part variance is the part mean square minus the error, over operators times trials, six. A negative one is set to zero. Here, repeatability's standard deviation is about zero point oh one eight mils, the operators add zero point oh one three five, and gauge R and R is about zero point oh two two. Very close to the average and range answer!
Three yardsticks and distinct categories
Now the three yardsticks. Percent contribution compares variances: gauge R and R variance over total variance. Here, zero point three six percent. Percent study variation compares standard deviations: zero point oh two two over zero point three six six, six percent. It's also called precision to total variation. And percent tolerance is six times the gauge R and R standard deviation over the tolerance: zero point one three three over one point five, eight point eight percent. That one is also called the precision to tolerance ratio, P over T.
One more number: the number of distinct categories. It equals one point four one times the part standard deviation over the gauge R and R standard deviation, rounded down. It's how many groups of parts the gauge can reliably tell apart. Here, one point four one times zero point three six six over zero point oh two two is about twenty three. You want five or more. Fewer than two, and the gauge can't tell one part from another!
Reading the result and deciding
So how do you decide? For percent study variation or percent tolerance: under ten percent is good, ten to thirty may be OK depending on the use and the cost, over thirty, fix the gauge first. For percent contribution, under one percent is good, over nine is a problem. Pick the yardstick by the job. Bad: one yardstick for every use. Good: percent tolerance for a pass or fail check, percent study variation and distinct categories for control charts and improvement projects. The new coating gauge passes all three!
Worked example 2: bias and linearity
Worked example two: bias and linearity. Passing gauge R and R says the gauge is precise. It doesn't say it's accurate. Priya takes five certified plastic shims, two, two and a half, three, three and a half and four mils, lays each one on a bare aluminum panel, and measures each five times. At the three mil shim she gets three point oh four, three point oh five, three point oh three, three point oh four and three point oh four.
Bias is the average reading minus the reference: three point oh four minus three, plus zero point oh four mils. Is that real, or luck? t equals the bias over s divided by the square root of n. The standard deviation is about zero point oh oh seven one, so the standard error is about zero point oh oh three two, and t is about twelve point six with four degrees of freedom. The critical t from a t table, or T dot INV dot two T of point oh five and four, is two point seven seven six. p is about zero point oh oh oh two. Reject: the gauge really does read high!
Now linearity: does the bias change across the range? The average biases are plus zero point oh two at two mils, then zero point oh three, zero point oh four, zero point oh five, and zero point oh six at four mils. Regress the twenty five biases on the reference values. The slope is zero point oh two: the bias grows by two hundredths for every mil. Its t is about ten point seven, with twenty three degrees of freedom, far past two point oh six nine. So the bias is real, and it isn't constant. That's a linearity problem!
Does it matter? Plus zero point oh four is under three percent of the tolerance. But near the bottom limit, a frame that's really two point four eight would read in spec. And it explains last week's mystery: the new gauge read high, not the old one low. The fix was cheap. Priya ran the maker's two-point calibration on the shims, then re-measured the three mil shim: average three point oh oh two, t about zero point five three, p about zero point six two. Fail to reject: no evidence of bias left. For stability, she'll measure that shim every Monday, and chart it on an individuals chart.
Special cases and software
A few special cases. Destructive tests, like a weld pull test, can't measure the same part twice. Use parts that are as alike as possible, in a nested design: each person gets their own parts. Comparing two gauges on the same parts is gauge correlation: a paired t test on the differences. And in a spreadsheet, AVERAGE, MAX minus MIN for the ranges, DEVSQ for sums of squares, F dot DIST dot R T for the ANOVA p-values, T dot INV dot two T for critical t, and SLOPE or LINEST for linearity.
Common mistakes
Now the common mistakes. One: ten nearly identical parts. If Priya had picked frames from one hour, with a spread of only zero point oh five mils, the same gauge would show forty percent study variation and just three distinct categories. Two: adding percent study variation like it's percent contribution. Standard deviations don't add, so those columns never sum to a hundred. Three: mixing five point one five and six. Older reports multiply by five point one five; check which one before you compare. Four: ignoring a significant interaction. And five: a passing gauge R and R with a biased gauge!
Recap
Let's recap. Variances add: gauge R and R squared is repeatability squared plus reproducibility squared. The average and range method uses R double bar, X diff and the range of the part averages, times K one, K two and K three. ANOVA turns mean squares into variance components, and checks the interaction first. Read the yardstick that fits the job, and want five or more distinct categories. Then check bias and linearity, because precise isn't the same as accurate!
Check yourself
Now, check yourself. A slat micrometer study gives a gauge R and R standard deviation of zero point oh two millimeters. The slat tolerance is one millimeter, eighteen and a half to nineteen and a half. What's the percent tolerance? A, two percent. B, twelve percent. C, twenty percent. Or D, one point two percent. Pause the video if you want to think about it.
The answer is B, twelve percent. Six times zero point oh two is zero point one two millimeters, and zero point one two over one is twelve percent. That's in the ten to thirty band, so it may be OK, depending on the use and the cost. A forgot the six. C used ten instead of six. And D slipped a decimal place.
That's gauge R and R by the numbers. Questions? Ask Q-Bot right here in the Academy. And one for the road: why does the good gauge get invited to every study? It gives the same answer, no matter who asks!
Independent study material; not affiliated with or endorsed by ASQ. Body of Knowledge codes identify where the topic appears in each certification's published outline.