Check · Test yourselfPractice tests

Academy › Topic library › Control Charts for Variables Data

Q-BOT ACADEMY · FREE VIDEO LESSON · 9 MIN

Control Charts for Variables Data

Variables data are measurements, like thickness, temperature or force. A variables control chart always comes as a pair. The top chart watches the center, the average. The bottom chart watches the spread, how scattered the readings are. Why two? Because a process can go wrong in two ways. Its average can shift, or it can get sloppier while the average stays put!

9:09 · Q-Bot · narrated, with worked example and a check-yourself question

In short

Variables charts come in pairs: one for the center, one for the spread. One reading at a time? Use I M R. Subgroups of two to about nine? X bar and R. Ten or more? X bar and S. Look up the constants for your subgroup size, and always read the spread chart first.

Check yourself

Weld pull tests at Brindlewood are five frames per lot, each one a force reading in pounds. Which chart fits best? A, individuals and moving range. B, X bar and R. C, X bar and S. Or D, a p chart.

Show the answer

The answer is B, X bar and R. Each lot is a subgroup of five measurements, right in the range chart's sweet spot. I M R is for single readings, X bar and S for ten or more, and a p chart counts defectives, not measurements.

Where this topic is taught

This lesson is part of every free Academy course whose Body of Knowledge covers it. Each course puts it in context, with exercises and checks.

Full lesson transcript

The narration from the video, by chapter. Brindlewood Outdoor Furniture and its people are a fictional company used in every Q-Bot Academy lesson.

Intro

It's Monday morning at Brindlewood Outdoor Furniture. Marcus is proud of his chart on mill one, five slats every hour. Lou walks over from the coating oven. "Nice chart. But I get one oven temperature a morning. I can't make a subgroup of five out of one number!" Then Priya chimes in. "And for the restaurant group, I'm measuring ten frames a shift. Does your chart still work for ten?" Good questions! They need different charts.

Hey there, I'm Q-Bot. Welcome to the Q-Bot Academy. Today: control charts for variables data. We'll cover what they are, why the right one matters, the three main charts, X bar and R, X bar and S, and individuals and moving range, and two worked examples at Brindlewood.

What it is

So, what are they? Variables data are measurements, like thickness, temperature or force. A variables control chart always comes as a pair. The top chart watches the center, the average. The bottom chart watches the spread, how scattered the readings are. Why two? Because a process can go wrong in two ways. Its average can shift, or it can get sloppier while the average stays put!

Why it matters

Why does picking the right chart matter? Because the wrong chart gives you the wrong limits. Too tight, and they cry wolf. Too wide, and a real problem slips by. At Brindlewood, a coating oven that runs cold for a few days means powder that isn't fully cured, and it chips. Those chairs come back to Hannah as complaints.

How it works: choosing and building the charts

Part one: choose the chart by how your data arrive. If you get one reading at a time, use the individuals and moving range chart, I M R for short. If you measure small subgroups, two to about nine pieces, use X bar and R. Five is the classic. If your subgroups are ten or bigger, use X bar and S. Bad: one favorite chart for everything. Good: let the subgroup size pick the chart!

Part two: the X bar and R chart. For each subgroup you plot two things: its average, called X bar, and its range, the biggest reading minus the smallest. The center line of the top chart is X double bar, the average of the averages. Its limits are X double bar plus or minus A two times R bar, the average range. The range chart runs from D three times R bar, which is zero for subgroups under seven, up to D four times R bar. That's the chart on mill one!

Part three: the X bar and S chart. Why switch when subgroups get big? A range uses only the biggest and smallest readings and ignores everything in between. The standard deviation, S, uses every reading, so the bottom chart plots each subgroup's S. The averages limits are X double bar plus or minus A three times S bar, and the S chart's limits are B three and B four times S bar. Bad: a range on subgroups of ten or more. Good: S, which uses all of them.

Part four: the individuals and moving range chart. Use it when data come one at a time: one reading a day, one per batch, or a slow or destructive test. The top chart plots each reading. The bottom chart plots the moving range, the difference between each reading and the one before it, always positive. The limits are the average plus or minus two point six six times the average moving range, and the moving range chart's upper limit is three point two six seven times that average. Bad: lump five days into a fake subgroup. That hides a bad day. Good: chart each reading as it comes. One caution: it's touchy with lopsided data, so check a histogram first.

Part five: read the spread chart first! The limits on the averages chart are built from R bar or S bar. If the spread is out of control, those limits can't be trusted. Bad: glance at the averages and move on. Good: check the range or S chart first, and only then the averages.

Part six: the constants. A two, D four, A three, B four and the rest come from a table, and they change with the subgroup size. Bad: use the A two for subgroups of five, point five seven seven, on subgroups of four. Good: look it up for your size. For four, A two is point seven two nine. The wrong one makes every limit wrong!

Worked example: the coating oven (I-MR)

Now, worked example one: Lou's oven. The coating oven is set at four hundred degrees Fahrenheit, and Lou reads it once every morning. One reading a day means I M R. After twenty mornings, the readings add up to an average of exactly four hundred degrees. Twenty readings give nineteen moving ranges, and they add up to forty five. Forty five divided by nineteen is about two point four degrees.

Now the limits. Two point six six times two point four is about six point four. So the upper limit is about four hundred six point four degrees, and the lower limit is about three hundred ninety three point six. For the moving ranges, three point two six seven times two point four is about seven point eight. All twenty mornings sit inside both charts. The oven is stable!

Then, on morning twenty three, the oven reads three hundred ninety one degrees. That's below the lower limit of about three hundred ninety three point six. And the jump from the morning before, three ninety nine to three ninety one, is a moving range of eight, above the limit of seven point eight. Two signals at once! Lou finds the gas pressure regulator on the burner sticking. He replaces it, Priya checks the cure on that morning's frames, and the next morning reads four hundred again.

Worked example: ten frames a shift (X-bar and S)

Worked example two: Priya's ten frames. For the restaurant group, Priya measures powder thickness on ten frames a shift, so it's X bar and S. After twenty five shifts, X double bar is three point oh oh mils and S bar is point one one mils. For subgroups of ten, A three is point nine seven five. Point nine seven five times point one one is about point one one. So the averages limits are about two point eight nine to three point one one mils. For the S chart, B four is one point seven one six and B three is point two eight four, so its limits are about point oh three to point one nine mils.

Two weeks later, one shift's average is a perfect three point oh oh mils. On the averages chart, nothing to see. But that shift's S is point two two, above the S chart's upper limit of point one nine. The coating got sloppier, even though the average looked fine! Priya finds a bent spacing bar letting some frames swing closer to the gun. Lou straightens it and adds a spacing bar check to the start-up checklist. That's why you read the spread chart first!

Common mistakes

A few common mistakes. One: the wrong chart for the subgroup size. Two: the wrong constant from the table. Three: only reading the averages chart and ignoring the spread. Four: building fake subgroups out of single readings taken days apart. And five: putting spec limits where the control limits belong.

Recap

Let's recap. Variables charts come in pairs: one for the center, one for the spread. One reading at a time? Use I M R. Subgroups of two to about nine? X bar and R. Ten or more? X bar and S. Look up the constants for your subgroup size, and always read the spread chart first.

Check yourself

Now, check yourself. Weld pull tests at Brindlewood are five frames per lot, each one a force reading in pounds. Which chart fits best? A, individuals and moving range. B, X bar and R. C, X bar and S. Or D, a p chart. Pause the video if you want to think about it.

The answer is B, X bar and R. Each lot is a subgroup of five measurements, right in the range chart's sweet spot. I M R is for single readings, X bar and S for ten or more, and a p chart counts defectives, not measurements.

Wrap-up

That's control charts for variables data. Questions? Ask Q-Bot right here in the Academy. And one for the road: why doesn't the moving range chart ever hold a grudge? Because it only remembers the last difference!

Independent study material; not affiliated with or endorsed by ASQ. Body of Knowledge codes identify where the topic appears in each certification's published outline.